LPS France

French Quality, Worldwide Efficiency

Area protected to date by LPS France ® solutions throughout the world

Lightning safety at exposed sites has returned to the forefront following a tragedy on November 9, 2026, in Malaysia. According to a November 10, 2026, dispatch from the Malaysian national news agency Bernama, citing the Sepang district police chief, three young men died after apparently being struck by lightning around 3:30 p.m. in Bandar Baru Salak Tinggi, Sepang, while they were taking shelter under a tree during heavy rain (Bernama, November 10, 2026). The New Straits Times reported the same facts (NST, November 2026).

Our thoughts are with the families. This article does not analyze the circumstances of the tragedy. However, it reiterates the official guidelines that apply to any site where people work or gather outdoors.

For site managers, installers and distributors, from Southeast Asia to Africa and Latin America, the question is a concrete one: where do people go when thunder roars, and is that place really safe?

Why is a tree never a safe haven from lightning?

A tree is never a safe shelter, as lightning preferentially strikes the tallest object in an area; the current can then reach a nearby person or travel through the ground. Official guidelines are unambiguous: never take shelter under an isolated tree (NOAA JetStream).

What official sources are saying

The U.S. National Weather Service (NWS) states that no outdoor location is safe when thunderstorms are present (NWS, Lightning Safety Overview). Furthermore, NOAA reminds us that lightning does not always strike the tallest object in general, but rather the tallest object in a given area.

In other words, a shelter that only protects from rain is not a shelter against lightning.

What constitutes a safe lightning shelter on a site?

A safe lightning shelter is a solid, enclosed building equipped with electrical and plumbing systems, or a vehicle with a rigid metal roof and closed windows. These are the two options recognized by NOAA and the U.S. Occupational Health and Safety Administration (OSHA). Everything else on the site should be considered hazardous during a thunderstorm.

Map the shelters before the storm season

On a construction site, solar power plant, logistics platform, or sports field, the nearest safe building may be several minutes away. Therefore, the first step is to identify safe shelters and estimate the time required to reach them. OSHA recommends that supervisors know, and communicate to their teams, the location of safe shelters and the time it takes to reach them.

  1. Identify each outdoor work or gathering area.
  2. Identify the nearest solid building or rigid-roofed vehicle for each zone.
  3. Measure travel time, including for groups and visitors.
  4. Clearly point out dangerous "shelters" (trees, kiosks, tents, open sheds) during briefings.

The role of physical protection

A lightning protection system is a set of interceptors, down conductors, and grounding systems designed to intercept a lightning strike and safely divert its current to earth. IEC 62305-3 (2024 edition) specifies the requirements for protecting structures against physical damage and living beings against touch and step voltages (IEC 62305-3:2024).

Therefore, when a building is designated as a refuge, its lightning protection must be assessed, maintained, and documented. Where applicable local regulations permit early streamer emission (ESE) lightning rods, the range Paraton@ir can be used in an installation designed and constructed in accordance with NF C 17-102:2011. This ESE-specific standard should be distinguished from the IEC 62305 series. However, no equipment can replace the decision to evacuate people to safety in a timely manner.

When to stop and resume outdoor activities?

Outdoor activity must cease as soon as thunder is heard or lightning is seen, as people are then likely within striking distance. It may not resume until 30 minutes after the last clap of thunder. This "30-minute rule," common to NOAA, NWS, and OSHA, must be included in the site's procedures.

A written lightning protection plan

OSHA recommends a written emergency action plan for outdoor work sites. Similarly, the NWS advises groups to have a lightning protection plan and to allow extra time when the group is large.

Supporting the decision through monitoring

Furthermore, a monitoring service can help the manager anticipate their decision. For example, LPS Sky Sentinel provides continuous, near real-time lightning monitoring within a 50 km radius, with updates every 60 seconds and an indicative estimate of the storm's arrival time based on storm cell tracking. Storm warning systems generally fall under IEC 62793. Nevertheless, such a tool only supports the plan: people must always be evacuated, and thunder heard on-site remains a reason to stop.

What should be checked on exposed sites after a storm?

After a thunderstorm, two priorities must be addressed: providing immediate assistance to the injured, and then inspecting any installations that may have been damaged. Lightning strike victims retain no electrical charge and can be touched safely; therefore, first aid can begin immediately (NWS). Technical inspections should only be carried out once the danger has passed.

First, the people

Next, the facilities

Next, a visual inspection of the exposed structures allows for the identification of any potential damage: loose fixings, damaged conductors, signs of arcing, or tripped protection devices. In particular, the lightning protection of buildings used as shelters must be checked as a priority by a qualified person.

Record site-by-site verification results, photos and follow-up actions.

Conclusion

The Sepang tragedy of November 9, 2026, reported by Bernama on November 10, 2026, serves as a stark reminder that a tree is never a safe haven from lightning. At exposed sites, safety relies on simple, written rules: designate sturdy buildings or vehicles with rigid roofs as shelters, cease operations as soon as thunder rumbles, and resume 30 minutes after the last clap of thunder. Physical protection conforming to IEC 62305-3:2024 or, for ESEs, to NF C 17-102:2011, and monitoring tools support this plan, but can never replace taking shelter in time. Finally, after every storm, people are prioritized, followed by infrastructure.

Frequently asked questions about lightning safety at exposed sites

Is it safe to take shelter under a tree if it's raining heavily?

No. Rain does not reduce the risk of lightning, and an isolated tree is one of the most dangerous places during a thunderstorm. NOAA recommends never taking shelter under an isolated tree.

Are open shelters or tents safe during a thunderstorm?

No. OSHA classifies sheds, kiosks, and tents as unsafe shelters. Only a solid, enclosed building or a vehicle with a rigid metal roof and closed windows is considered safe.

How long should I wait before going out again?

At least 30 minutes after the last clap of thunder, according to NOAA, NWS and OSHA.

Sources