LPS France

French Quality, Worldwide Efficiency

Area protected to date by LPS France ® solutions throughout the world

When discussing lightning protection systems , two main philosophies are generally distinguished. On the one hand, there's active protection , which uses an early streamer emission (ESE) lightning rod to anticipate and capture the lightning strike. On the other hand, there's passive protection , which relies on a mesh cage to enclose and secure a structure. The choice between the two is never arbitrary: it depends on the building's architecture, the actual risk level, and the project constraints.

Why choosing the right lightning protection system is so important

Lightning strikes near a building with lightning protection, under a stormy sky.

Think of lightning as a raw, natural force, always seeking the most direct path to the ground. A well-designed lightning protection system (LPS) acts as a guide, a safe passage that intercepts this immense energy and disperses it safely into the ground. Without this guide, the consequences can be catastrophic.

Protecting oneself effectively is a necessity for several fundamental reasons:

Each territory has its own level of risk

The need for protection is not the same everywhere, far from it. The risk of lightning is closely linked to geography and local weather. In France, for example, the density of lightning strikes is very heterogeneous. Bourgogne-Franche-Comté is the most exposed region with 1,243 strikes/km²/year , while Normandy is much less exposed with 0,518.

This on-the-ground reality is a decisive factor in choosing a system. A local risk analysis is not optional; it is an essential step. For more information, you can consult the complete report on lightning strikes in France.

This guide is designed to shed light on the fundamental differences between the types of lightning protection systems. It will give you the keys to understanding the advantages of each technology and the criteria that will allow you to make an informed choice, whether you are an engineer, architect, or site manager.

The goal is not just to install a system, but to install the right system, one that is perfectly tailored to the specific needs of your structure and its environment.

We will therefore explore in detail the two main approaches: active protection with the early streamer emission (ESE) lightning rod and passive protection with the meshed cage.

Understanding the ESE lightning rod: active and targeted protection

Unlike passive systems that simply "wait" for lightning to strike, early streamer emission (ESE) lightning rods completely change the game. They adopt a proactive strategy. In short, they don't just react to the impact; they anticipate it and guide it along a controlled path.

This is the very heart of active protection. It's not just about reinforcing walls; it's about placing a vigilant guardian who detects threats and intercepts them before they can cause damage. The ESE works exactly like that.

The secret to early seed funding

The entire performance of the PDA relies on a key technological advantage: the lead time to ignition , denoted Δt . When the atmosphere becomes charged and a lightning strike is about to occur, the electronic device of the lightning rod activates. Just before the downward leader of the lightning strikes the ground, the PDA takes the lead by generating its own upward leader.

This tracer "rises to meet" the lightning, creating an ionized path much faster than a simple metal point. This brief moment of anticipation, measured in microseconds (µs), constitutes the crucial Δt. Thanks to this, the ESE detects lightning well above the structure it protects.

It is this ability to create a controlled point of impact that defines the effectiveness of a ESE lightning rod. It does not simply protect the point where it is installed; it extends its protection over a vast circular area.

This technological advantage allows for a much larger protection radius (Rp) find out more about early streamer emission (ESE) lightning rods .

The essential components of a ESE setup

A PDA installation compliant with the NFC 17-102 is not just a lightning rod; it's a complete system where each component plays a vital role. Overall performance depends on the quality of each component and, above all, on its implementation.

It can be summarized in four pillars:

These elements are completely interdependent. An excellent lightning rod with a poor ground connection is useless.

Practical applications of the ESE lightning rod

Thanks to its versatility and efficiency, the ESE has become the solution of choice for a multitude of organizations. Its low visual impact and ability to cover large areas make it particularly relevant in many scenarios.

Let's take the bell tower of a historic church . Installing a mesh cage there would be a technical nightmare, very expensive, and would spoil the monument's aesthetics. A single PDA, discreetly installed at the top, is enough to protect the entire structure.

Another scenario: a large industrial site with multiple buildings and open-air storage areas. Using multiple PDAs allows for the creation of overlapping protection zones, thus ensuring complete coverage with a much lighter infrastructure than a full mesh network.

Innovation continues to enhance the reliability of these systems. Solutions like the Contact@ir from LPS France add connected monitoring. This device continuously checks the lightning rod's health, counts lightning strikes, and sends real-time alerts. This predictive maintenance ensures that protection is always operational and offers unparalleled peace of mind.

The meshed cage: passive and complete protection

Large metallic Faraday cage on a flat roof, protecting equipment from lightning strikes, with a green field in the background.

While the PDA lightning rod is an active interceptor, the mesh cage takes a radically different approach. It embodies passive protection in its purest and most complete form. Rather than creating a single point of impact, it acts as a true metallic shield that envelops the building.

This system doesn't try to "attract" lightning; it receives it at any point on its surface. The energy is then instantly distributed across a dense network of conductors and safely guided to the ground. It's essentially the same principle as the famous Faraday cage , but applied on a building scale.

The objective is twofold: to intercept the lightning strike wherever it hits, and to immediately divide its current into a multitude of lower-intensity paths. This distribution drastically reduces the risk of breakdowns and devastating overvoltages inside the building. This entire method is rigorously governed by the international standard IEC 62305 .

Anatomy of a meshed cage

A meshed cage installation is a true protective architecture. It consists of several interconnected elements that form a continuous conductor mesh around the structure. Each piece of the puzzle is crucial for the efficient dispersion of lightning current.

Thanks to this design, no point in the building receives the full electrical charge of the impact, thus protecting its integrity as well as that of the equipment it houses.

When is a meshed cage essential?

While the ESE shines with its discretion and wide coverage area, the meshed cage is essential in scenarios where risk tolerance is close to zero and where internal protection is as critical as external protection.

The meshed cage is the reference solution for sites where business continuity is non-negotiable and where the slightest overvoltage can have catastrophic consequences.

Here are some typical cases where a wire cage becomes the obvious choice:

For a detailed overview of the options, you can consult the technical information on mesh cage solutions that meet the strictest standards.

Constraints to consider

Despite its formidable efficiency, the mesh cage is not without its drawbacks. Its visual impact is far greater than that of a PDA. The network of conductors on the roof and the multiple drops on the facades can detract from a building's aesthetics, which can be a hindrance for architectural projects or historical monuments.

Furthermore, its installation is more complex and often more expensive . It requires a greater quantity of materials and more labor. The design must be meticulously integrated into the building plans, making it more suitable for new construction than renovations. This balance between maximum performance and practical constraints will guide the final choice.

Comparing ESE systems and the meshed cage

Choosing between an early streamer emission (ESE) lightning rod and a meshed cage is a bit like choosing between a high-precision sniper rifle and a full-body shield. Each system has its own philosophy and addresses very specific needs. The final decision will always depend on a thorough analysis of several criteria, from the building's geometry to the level of risk one is willing to accept.

This direct comparison will help you weigh the pros and cons of each solution. Together, we'll break down the factors that guide the choice of a professional: the protected area, the complexity of the installation, the aesthetic impact, the overall cost, and, of course, the regulations that govern everything.

The extent of protection

The ESE excels in its ability to cover very large areas. Thanks to its early warning (Δt), it can secure a wide protection radius (Rp) with a single capture point. It is the ideal solution for tall, isolated structures, large flat roofs, or open sites such as stadiums or solar farms.

The meshed cage, on the other hand, protects by enveloping. Its protection zone coincides precisely with the contours of the building it covers. It protects nothing beyond its own physical footprint, but in return, it guarantees that every square centimeter of the structure is fully covered.

The complexity of the installation

Installing a lightning rod is generally simpler and faster. In short, a lightning rod is installed at a high point, two down conductors are run, and an effective ground connection is ensured. This simplicity makes it a very attractive option for existing buildings, where a more complex intervention would be complicated.

Therefore, installing a meshed cage is a completely different matter. It's a much more complex operation that requires creating a conductor mesh across the entire roof, attaching numerous down conductors to the facades, and installing a grounding loop all around the building. This type of work is much more easily integrated into the construction of a new building.

The impact on architecture

From an aesthetic point of view, the ESE is often the clear winner. Discreet, it consists of a point at the top of a mast, thus preserving the visual integrity of most architectural styles. For historical monuments or buildings with highly refined designs, this is a significant advantage.

The meshed cage, on the other hand, has a much more pronounced visual impact. The grid on the roof and the multiple cables that descend along the walls are clearly visible and can be perceived as a real aesthetic constraint on certain projects.

The choice is not only technical, it is also architectural. A lightning protection system must be effective without altering the character of the building it protects.

The overall cost of the project

The overall cost – which includes equipment purchase, installation, and maintenance – is another decisive factor. Generally, a PDA system is more economical than a mesh cage, especially when it comes to protecting large areas. It simply requires less material (copper, aluminum) and less labor.

The meshed cage, due to the large number of conductors and the longer installation time, represents a higher initial investment. However, this cost can be justified for highly critical sites, where redundancy and lightning current distribution are absolute requirements.

The regulatory framework

This is a fundamental point: the two systems do not meet the same standards.

The choice of standard to apply may depend on the requirements of the specifications, local regulations or the recommendations of your insurer.

Comparative Table: ESE Lightning Rod vs. Meshed Cage

To summarize, nothing beats a table. This table highlights the key differences between the two systems to help you choose the most appropriate lightning protection solution.

Criteria Early Streamer Emitter Lightning Rod (ESE) Meshed Cage (Franklin Spikes)
Principle Active protection, anticipates and creates a controlled point of impact. Passive protection, intercepts the impact anywhere on its surface.
Protection zone Large protection radius (Rp), ideal for large areas and open spaces. Limited to the building's footprint, complete protection by wrapping.
Complexity Simpler and faster installation, with fewer components. A more complex installation, requiring a complete mesh and multiple descents.
Visual impact Low and discreet, preserving the architectural aesthetics. Most importantly, with a network of conductors visible on the roof and facades.
Cost Generally more economical, requiring less equipment and labor. Higher initial investment due to the quantity of materials.
Reference standard NFC 17-102 IEC 62305
Ideal applications Industrial sites, bell towers, stadiums, tall buildings, historical monuments. Hospitals, data centers, ATEX sites, buildings with sensitive equipment.

Ultimately, ESEs are often the preferred solution due to their effectiveness over large areas and their discreetness, while meshed cages remain the gold standard for comprehensive and redundant protection of the most critical structures. The right choice will always depend on a thorough risk analysis.

Select the lightning protection system that best suits your project

Choosing between different types of lightning protection systems is never a random decision. It is a purely technical matter that must be based on a methodical analysis of the specific risks to your site. The cornerstone of this process is the Lightning Risk Analysis (LRA) , a step mandated by the IEC 62305-2 standard.

Far from being a mere administrative formality, the ARF is a genuine diagnostic tool. It is what will allow us to understand the true vulnerability of your structure by examining a multitude of parameters.

Think of a doctor who analyzes all the symptoms before prescribing the right treatment. The ARF does exactly the same thing for your building, by thoroughly examining:

Define the required level of protection

Once all these elements are compiled, the ARF gives us a verdict: a required level of protection, classified from I to IV. This level is not just a number, it defines a very precise technical specification for the design of the entire system.

The level of protection is like a slider that adjusts the intensity of the defense to the level of the threat. It ensures that the solution is perfectly sized: neither underestimated, which would be dangerous, nor overestimated, which would represent an unnecessary cost.

This classification from I to IV reflects real-world conditions. The four protection levels defined by the NF EN 62305-2 standard offer varying levels of effectiveness, ranging from 81% (Level IV) to 98% (Level I). The choice depends directly on the ARF's findings, allowing the investment to be tailored to the criticality of the area being protected. It's important to remember that even the highest level cannot guarantee absolute protection, given the complexity of the lightning phenomenon.

A decision tree to guide you

To gain a clearer understanding, the choice can often be summarized by a central question: should we adopt an active (with a PDA) or a passive one (with a mesh cage)? A simple decision tree allows us to quickly visualize the logic to follow.

Here is how we can diagram the reflection between a ESE lightning rod and a meshed cage, according to the characteristics of the project.

Decision tree comparing directional ESE and meshed cage options for coverage and environmental requirements.

This diagram clearly illustrates that ESEs are often the preferred solution for isolated structures or when aesthetics are a key consideration. Conversely, meshed cages become almost indispensable for ensuring complete coverage of highly sensitive sites.

To make the right choice, it's also helpful to understand the overall dynamics of construction projects. Taking a look at a comprehensive guide to the construction market can provide excellent insight into the context in which these decisions are made.

It is precisely at this stage that the expertise of a specialist like LPS France becomes crucial. From the initial audit with the ARF to the detailed system design, our support guarantees that each component is chosen and sized to offer the most reliable protection, the one that truly meets your needs.

Ensure lasting protection with connected maintenance

Installing one of the types of lightning protection systems is only half the battle. For protection to be truly effective in the long term, it must be flawless at all times. This is where maintenance comes in, a non-negotiable step to guarantee the safety and compliance of your installation.

Imagine your lightning protection system as a soldier on the front lines. It's constantly exposed to the elements: rain, wind, corrosion, and of course, lightning strikes themselves. Inevitably, it wears out. A simple loose connection or an increased ground resistance is enough to render the entire system inoperable, leaving it blind to the threat.

Standards, such as NFC 17-102 , exist for a reason. They mandate regular checks to ensure the system remains functional. These inspections are essential for the safety of property and people. By ensuring a professional and compliant installation, tradespeople also guarantee the durability and reliability of the systems, a crucial step often covered by ten-year liability insurance .

The contribution of connected maintenance

Traditional maintenance is a bit like an annual health check-up. You perform a check-up on a fixed date. The problem? A fault can easily appear the day after the visit and go unnoticed for months, leaving the site completely vulnerable. To overcome this limitation, LPS France has developed the Contact@ir digital .

This system transforms a passive installation into an active and intelligent guardian. Instead of waiting for someone to check its status, it constantly monitors its vital control points itself.

The goal of connected maintenance is simple: to move from a reactive to a proactive approach. Instead of simply noting a problem during a visit, you are alerted in real time as soon as it occurs.

Contact@ir system 24/7 monitoring , centralized via the LPS Manager . It fulfills several key missions:

This technology provides complete peace of mind. It not only guarantees compliance with standards, but above all, it assures you that your protection is functional precisely when you need it most.

We answer your questions about lightning protection

To help you gain a clearer understanding, we've compiled the most frequently asked questions here. Our goal: to provide straightforward, jargon-free answers to help you make the right decisions.

Does a lightning rod really attract lightning?

It's a persistent misconception, but the answer is no. A lightning rod, whether it has an early streamer emission (ESE) device or a simple point, does not have the power to attract a lightning bolt that would not have struck anyway.

Its role is far more subtle: it simply provides an easier and safer path for a lightning strike that is already about to hit its protection zone. In a way, it acts as a preferential and controlled point of impact, channeling the energy towards the ground to prevent it from spreading chaotically and destructively throughout the building.

Can I install a lightning protection system myself?

Installing lightning protection is a job for specialists. It's a technical and complex operation that absolutely must be carried out by qualified and certified professionals.

Therefore, complying with standards, such as NFC 17-102 for PDAs or IEC 62305 for mesh cages, is not a mere administrative formality. It is the only guarantee that your installation will be truly effective on the day. A poorly executed installation, particularly one with a faulty ground connection, can render the system completely inoperative, or even worsen the danger.

What is the lifespan of an installation?

A well-designed and well-maintained lightning protection system is built to last, often for decades. The materials used, such as copper or aluminum conductors, are extremely durable.

However, its longevity depends directly on the rigor of its maintenance. Regular checks, at least once a year , are essential to verify electrical continuity and the quality of the grounding. This is where connected systems like Contact@ir become truly valuable by radically simplifying this monitoring.

A good installation is a long-term investment, but only rigorous maintenance guarantees its performance over the years.

Should the equipment inside also be protected?

Absolutely, and this is a crucial point that is often overlooked. The lightning rod on the roof handles the direct impact; it's the first line of defense. But a lightning strike, even nearby, generates violent power surges that travel through electrical and communication networks.

Without surge protectors installed on your electrical panels, these power surges act like a fatal electric shock to your sensitive electronic equipment (computers, servers, PLCs, etc.). Complete and consistent protection therefore systematically combines an external system (lightning rod) and internal protection (surge protectors).


For a comprehensive analysis of your needs and the design of a customized solution, trust the expertise of LPS France . Discover our innovative solutions at https://lpsfr.com .