LPS France

French Quality, Worldwide Efficiency

Area protected to date by LPS France ® solutions throughout the world

The risk of lightning strikes in India was once again highlighted on November 16, 2026, by the Raipur-based daily newspaper The Hitavada. According to the newspaper, lightning caused more than 900 deaths in the state of Chhattisgarh over five years, from October 2021 to September 2026 (The Hitavada, November 16, 2026).

This figure is a cumulative total over five years, not the result of a single storm. The same article indicates that 434 deaths were recorded between July 2024 and June 2026, and that the state government has released 17.28 crore rupees in aid to the victims' families.

For installers, distributors, and site managers, in South Asia and elsewhere, the question is a practical one: How can people and buildings be prepared before, during, and after a storm? This article answers this question based solely on official guidelines.

What does the rapid assessment of Chhattisgarh show?

The statistics from Chhattisgarh show that lightning remains a major danger, both in rural areas and cities. According to The Hitavada, more than 900 people died from lightning strikes between October 2021 and September 2026, in almost every district of the state. The newspaper notes that awareness campaigns alone have not been enough.

Key figures reported by The Hitavada

Furthermore, the newspaper reports that weather experts consider lightning detectors useful as early warning systems to prevent such disasters. These figures and opinions are those of the newspaper and the experts it cites.

Why this is important for sites

Construction sites, farms, schools, industrial areas, and telecom towers all host people who work or gather outdoors. That's why every site located in a storm-prone region needs a written lightning protection plan. This plan combines the physical protection of buildings with clear safety rules for people.

What should a site do before the storm season?

Before the storm season, a site designates safe shelters, checks its grounding and lightning protection, and trains staff on the 30-30 rule. The Indian National Disaster Management Authority (NDMA) recommends maintaining grounding and considering lightning rods and surge protectors (NDMA, Be Smart Be Prepared).

Preparation list

  1. List each outdoor work area, assembly point and access route of the site.
  2. Designate a permanent building as a shelter for each zone, and measure the time required to reach it.
  3. Check the grounding, down conductors and capture devices of buildings used as shelters.
  4. Explain the 30-30 rule to all staff, subcontractors and visitors.
  5. Name the person who gives the order to stop and the person who authorizes the resumption.

The 30-30 rule in practice

The NDMA presents the 30-30 rule as an important lightning safety guideline. After a flash of lightning, count to 30; if thunder occurs before 30, go indoors. Furthermore, activities should be suspended for at least 30 minutes after the last clap of thunder.

Don't wait until you reach that threshold: take shelter as soon as thunder is audible.

How can we protect buildings used as shelters?

These buildings are protected by a lightning protection system designed according to recognized standards. A lightning protection system combines lightning rods, down conductors, and grounding points, which intercept lightning and divert its current to earth, with equipotential bonding within the structure. It is the responsibility of qualified professionals.

Which standards apply?

Choosing the right equipment

For example, a school, health center or living base serving as a refuge needs capture devices, descents and an earth connection sized for the structure.

However, a properly designed, installed, and maintained lightning protection system reduces the risks to the structure and its occupants, but does not eliminate all risk. It does not replace the need to shelter people outdoors in a designated safe refuge.

What to do during a thunderstorm?

During a thunderstorm, you should immediately go inside a house or sturdy building and stay there. The NDMA recommends not taking shelter under a tree, avoiding structures with metal roofs, and staying away from bodies of water and power lines. Outdoor work should stop until the danger has passed.

Official NDMA guidelines for outdoor use

Official NDMA instructions inside

What should you check after a storm?

After a storm, the first priority is people to seek help and call emergency services immediately. The NDMA recommends performing cardiopulmonary resuscitation (CPR) if necessary and seeking medical attention without delay. Next, locate and report any downed power lines and trees. Only then should a qualified professional inspect the installations.

First, the people

Next, the facilities

Next, a visual inspection identifies any damage: loose fasteners, damaged conductors, signs of arcing, or tripped protective devices. In particular, the protection of buildings used as shelters must be checked as a priority. Finally, each inspection is documented, with photos and follow-up actions, site by site.

Lightning protection installation checks should never take place in the event of a thunderstorm threat (IEC 62305-3:2024).

What LPS France offers in the face of lightning risk

These deaths were not inevitable. With a timely warning, everyone could have been alerted and taken to safety. That is exactly the purpose of the solutions from LPS France.

These tools help in decision-making; they do not replace NDMA guidelines or the physical protection of buildings.

Conclusion

The report published by The Hitavada on November 16, 2026, showing more than 900 lightning deaths in Chhattisgarh between October 2021 and September 2026, serves as a reminder that lightning is a daily danger to outdoor sites.

Preparedness relies on official guidelines: the NDMA's 30-30 rule, sheltering in sturdy buildings, and immediate first aid. Physical protection designed in accordance with IEC 62305 (2024 edition) or, for ESEs, NF C 17-102:2011, reduces risks to shelter buildings and their occupants. Monitoring tools help to decide earlier when to stop work, but it is ultimately the responsibility of those in charge to ensure everyone is safely sheltered in time.

Frequently asked questions about lightning risk in India

What is the 30-30 rule recommended by the NDMA?

After a flash of lightning, count to 30. If thunder is heard before 30, go inside, and suspend activities for at least 30 minutes after the last clap of thunder.

Is it possible to take shelter under a tree or under a sheet metal shelter?

No. The NDMA recommends not taking shelter near or under a tree and staying away from structures with sheet metal or metal plate roofs.

Does a lightning protection system protect people outside?

No. A complete installation reduces risks to the structure and its occupants, but does not replace the procedure for sheltering people outdoors. They must reach a safe shelter.

Sources