Compt@ir ® lightning strike counter – impact detector

  • Ref. 43603/ CMPTD
  • Lightning strike counter with digital display
  • Can be positioned on all types of existing conductors (flat, round, etc.)
  • Option : Contact@ir System communication system
  • Dimensions: 70x50x60 mm
  • Weight: 0.330 kg

Lightning strike detector and counter with digital display. Connected product (IOT) optional.

Complies with standard NF EN 50164-6 (IEC 62561) and equivalent country standards.

Download the documentation in French

Download the documentation in English

Download the technical sheet

 

Add to quote

Description

Compt@ir ® lightning strike counter – impact detector

The “made in France” counter:

The Compt@ir ® lightning strike counter displays the total impacts hitting the lightning rod installation thanks to its digital display on the front panel. Each time a lightning strike is detected, it automatically increments one unit on the display. Sure enough, the rightmost number adjusts accordingly. This display operates on a battery that is replaceable approximately every 10 years at the factory.

However, battery depletion does not affect the impact measuring device in the meter. Equipped with a Contact@ir ® MD or Contact@ir ® transmitter (with Rout@ir ®), the Compt@ir ® acts like an Alert@ir XT®. Its technology makes it possible to detect positive and negative lightning strikes. Finally, we manufacture the Compt@ir ® in our workshops in France.

Its universal installation:

The Compt@ir ® impact counter is installed in series on a lightning current down conductor. About 2 meters from the ground, without the need to cut the conductor. In general, it is installed above the control joint, where its inclined screen makes reading easier. Thanks to its universal fixings, this meter adapts and works with all types of existing conductors, whether flat or round. Its innovative technology makes it possible to detect both positive and negative lightning strikes. Finally, our Compt@ir ® impact counters are not only waterproof, robust and reliable; they also comply with current standards, such as NFC 17-102:2011 and NF EN 50164-6, thus guaranteeing total compliance and maximum reliability.

Its usefulness for maintenance:

Regular observation of the display is necessary for proper monitoring of the lightning rod installation. The lightning strike counter is essential for the proper maintenance of the lightning protection system (see NFC 17-102:2011: carry out a check after each lightning strike).

Optional, this regular check. In fact, our range of transmitters and receivers Contact@ir ® System sends a real-time alert for each lightning strike detected. Our impact meter therefore detects the lightning current on any lightning rod conductor, but also measures it (in kA). Additionally, we record the timestamp of each impact.

In conclusion, the Compt@ir ® is essential and its function/price ratio is very advantageous since it becomes a witness to past lightning events. If you buy it with a communication solution  Contact@ir ® System, then the lightning strike counter becomes the monitor of your installation. Receive real-time information on LPS Manager.

Further information

Weight 0.330 kg
Dimensions 70 × 50 × 60mm