Galvanized steel lightning rod lifting mast – 2nd element

  • Ref. 11222/MAT-GE2
  • Material: galvanized steel
  • Overall length 2.00 m
  • Adaptation for the first element mast
  • Dimensions: 2000×42 mm
  • Weight: 5 kg
  • Partners with the third element mast

 

Download the technical specifications

The second galvanized steel mast element is approximately 3.8 m high: 

Second galvanized steel lifting mast section to be coupled with a first section to support an Ellipsor Paraton@irEarly Streamer Emission (ESE) lightning rod. The lightning rod lifting mast increases the lightning protection zone by raising the lightning rod above the structure. It optimizes the lightning rod's placement for better interception of atmospheric electrical discharges and helps prevent direct lightning damage to buildings.

Compliance with NFC 17-102:2011 and IEC 62305 standards and equivalent country standards

 

Add to quote
SKU: 11222 Category :

Description

Galvanized Steel Lightning Rod Elevating Mast – Second Element:

The second lightning rod lifting mast element is made of galvanized steel. It has a length of 2.00 meters and an outside diameter of 42 mm. This mast is specially designed to fit the first element mast for the elevation of the ESE Ellips® and Paraton@ir® Early Streamer Emission (ESE) Lightning Rods.

Facility:

Its installation is easy and safe for raising a lightning rod to approximately 3.8 meters (for example, on a house). Longitudinal clamping screws are used to secure the first and second mast sections. Furthermore, this mast can be assembled with a third section to achieve a total height of 5.7 meters (for example, on a hospital, factory, or building). Finally, we also offer a stainless steel version, ideal for environments prone to corrosion.

Lightning Rod Elevation – Increased Protection Radius:

Thus, to further increase the height, we add a third mast element to reach a height of 5.7 meters. Therefore, the modularity of this assembly offers precise adaptability to the needs of achieving a greater Protection Radius with a Protection Level constant.

Choose a system of mast fixings tailored to your project.

Stable and robust, our lightning rod elevation mast generally does not require a guying kit when used with our lightning rods.

Benefits:

Thus, the lightning rod elevation mast plays several key roles in lightning protection. It expands the protection zone by raising the lightning rod above the buildings. Consequently, the radius of lightning protection coverage is effectively increased.

This optimized positioning allows for more strategic interception of electrical discharges, thus providing better protection. The lightning rod captures and channels the direct impacts of lightning and its energy away from vulnerable areas, thereby protecting the underlying structure.

Namely:

In addition to its functionality, the design of the lightning rod's lifting mast has been carefully considered. Indeed, its aesthetics are designed to harmonize with the surrounding architecture, combining protection and style. (House, Historic Building, Hospital, Apartment Building, Factory…)

Thanks to its composition, this mast is a "natural conductor". (IEC 62305 and NFC 17-102:2011 standards).

Finally, for even greater integration, the mast can be painted. This allows for customization according to the preferences or architectural requirements of the project.

Additional information

Weight 5 kg
Dimensions 2000 × 42 mm